Size: a a a

2021 January 27

N

Nikolay Kulikov in VMware vSAN
uncleroot
а там точно только витнесс ходит?
конечно
источник

KS

Kirhy Stoff in VMware vSAN
Bandwidth between sites hosting VM objects and the witness nodes are dependent on the number of objects residing on vSAN. It is important to size data site to witness bandwidth appropriately for both availability and growth. A standard rule of thumb is 2Mbps for every 1000 components on vSAN.
источник

N

Nikolay Kulikov in VMware vSAN
там идет по одному heartbeat каждые 5 секунд  на каждый объект (fixed)
источник

u

uncleroot in VMware vSAN
Kirhy Stoff
Bandwidth between sites hosting VM objects and the witness nodes are dependent on the number of objects residing on vSAN. It is important to size data site to witness bandwidth appropriately for both availability and growth. A standard rule of thumb is 2Mbps for every 1000 components on vSAN.
о, бевакаш, видимо проглядел
источник

N

Nikolay Kulikov in VMware vSAN
источник

N

Nikolay Kulikov in VMware vSAN
Nikolay Kulikov
там идет по одному heartbeat каждые 5 секунд  на каждый объект (fixed)
во, нашел - The required bandwidth between the Witness and each site is equal to ~1138 B x Number of Components / 5s
источник

N

Nikolay Kulikov in VMware vSAN
источник

N

Nikolay Kulikov in VMware vSAN
ну еще обычно от сайта до HQ есть трафик управления от vCenter, но там тоже копейки - https://www.vmware.com/content/dam/digitalmarketing/vmware/en/pdf/techpaper/performance/robo-vcenter67-perf.pdf
источник

u

uncleroot in VMware vSAN
Nikolay Kulikov
во, нашел - The required bandwidth between the Witness and each site is equal to ~1138 B x Number of Components / 5s
++
источник

N

Nikolay Kulikov in VMware vSAN
Kirhy Stoff
Bandwidth between sites hosting VM objects and the witness nodes are dependent on the number of objects residing on vSAN. It is important to size data site to witness bandwidth appropriately for both availability and growth. A standard rule of thumb is 2Mbps for every 1000 components on vSAN.
Ну 1000 компонентов - многовато для 2-х узлового robo сайта. Обычно там раз в 5-10 меньше.
источник
2021 January 28

N

Nikolay Kulikov in VMware vSAN
vRealize AI
источник

MD

Mista D in VMware vSAN
источник
2021 January 29

VK

Victor Konovalov in VMware vSAN
источник
2021 February 01

VK

Victor Konovalov in VMware vSAN
источник

GN

Grigory Nikonorov in VMware vSAN
Есть кто живой?
источник

GN

Grigory Nikonorov in VMware vSAN
Поломалась vmfs на одном из датасторов у коллег, нужен порядок действии при восстановлении
источник

GN

Grigory Nikonorov in VMware vSAN
Vsphere 6.7
источник

N

Nikolay Kulikov in VMware vSAN
Шаг первый - открыть кейс в GSS
источник

N

Nikolay Kulikov in VMware vSAN
Шаг второй - действовать согласно их инструкции
источник

GN

Grigory Nikonorov in VMware vSAN
Коля, привет!) Ок, уже открывают коллеги
источник